ABB Component Drives ACS150, 0.5hp to 5hp Technical Guide

Technical data

Cooling
The ACS150 is configured with cooling fans as standard. The cooling air must be free from corrosive materials and must not be above the maximum ambient temperature of 40°C (50°C with derating). For more specific limits see the Technical specification – Environmental limits in this catalog.

Cooling air flow

Type Code Frame
Size
Heat Dissipation Air Flow
W BTU/Hr m3/h ft3/min
1-phase supply voltage 200 – 240 V units
ACS150-01U-02A4-2 R0 25 85 -* -*
ACS150-01U-04A7-2 R1 46 157 24 14
ACS150-01U-06A7-2 R1 71 242 24 14
ACS150-01U-07A5-2 R2 73 249 21 12
ACS150-01U-09A8-2 R2 96 328 21 12
3-phase supply voltage 200 – 240 V units
ACS150-03U-02A4-2 R0 19 65 -* -*
ACS150-03U-03A5-2 R0 31 106 -* -*
ACS150-03U-04A7-2 R1 38 130 24 14
ACS150-03U-06A7-2 R1 60 205 24 14
ACS150-03U-07A5-2 R1 62 212 21 12
ACS150-03U-09A8-2 R2 83 283 21 12
3-phase supply voltage 380 – 480 V units
ACS150-03U-01A2-4 R0 11 38 -* -*
ACS150-03U-01A9-4 R0 16 55 -* -*
ACS150-03U-02A4-4 R0 21 72 -* -*
ACS150-03U-03A3-4 R1 31 106 13 8
ACS150-03U-04A1-4 R1 40 137 13 8
ACS150-03U-05A6-4 R1 61 208 19 11
ACS150-03U-08A8-4 R1 94 321 24 14
* Frame size RO with free convection cooling.

Free space requirements

Enclosure Type Space Above
mm/in
Space Below
mm/in
Space on Left/Right
mm/in
All Frame Sizes 80/3.15 80/3.15 0/0
Fuses
Standard semi-conductor fuses can be used with the ACS150. Recommended fuse ratings are show in the table below.

Selection table

Type Code Frame
Size
IEC Fuses UL Fuses
A Fuse
Type*
A Fuse
Type*
1-phase supply voltage 200 – 240 V units
ACS150-01U-02A4-2 R0 10 gG 10 UL class T
ACS150-01U-04A7-2 R1 16 gG 20 UL class T
ACS150-01U-06A7-2 R1 20 gG 25 UL class T
ACS150-01U-07A5-2 R2 25 gG 30 UL class T
ACS150-01U-09A8-2 R2 35 gG 35 UL class T
3-phase supply voltage 200 – 240 V units
ACS150-03U-02A4-2 R0 10 gG 10 UL class T
ACS150-03U-03A5-2 R0 10 gG 10 UL class T
ACS150-03U-04A7-2 R1 10 gG 10 UL class T
ACS150-03U-06A7-2 R1 16 gG 15 UL class T
ACS150-03U-07A5-2 R1 16 gG 15 UL class T
ACS150-03U-09A8-2 R2 16 gG 20 UL class T
3-phase supply voltage 380 – 480 V units
ACS150-03U-01A2-4 R0 10 gG 10 UL class T
ACS150-03U-01A9-4 R0 10 gG 10 UL class T
ACS150-03U-02A4-4 R0 10 gG 10 UL class T
ACS150-03U-03A3-4 R1 10 gG 10 UL class T
ACS150-03U-04A1-4 R1 16 gG 15 UL class T
ACS150-03U-05A6-4 R1 16 gG 15 UL class T
ACS150-03U-08A8-4 R1 20 gG 25 UL class T